450/750 V Halogen Free & Flame Retardant Single Core Cables (HF NYA)

H07Z1-U, H07Z1-R (TSE)

450/750 V halogen free and flame retardant single core cables are designed for
electrical installations where enhanced fire safety and low smoke emission are
required. These cables are manufactured with copper conductors and halogen-free
insulation materials that minimize toxic gas release in case of fire.

Thanks to their flame retardant properties and environmentally friendly structure,
these cables are especially suitable for installations in public buildings,
commercial facilities, and areas with high human occupancy.

Applications

  • Electrical installations in public buildings
  • Commercial and residential buildings
  • Hospitals, schools, and shopping centers
  • Industrial control panels and switchboards
  • Areas requiring low smoke and toxic gas emission

Halogen free single core cables are widely used in applications where fire safety,
low smoke density, and reduced toxic gas emission are critical for human safety.

Cable Construction

  • Conductor: Solid copper conductor
  • Insulation: Halogen free, flame retardant compound
  • Core Identification: Color coded

Halogen free single core cables are manufactured using special insulation compounds
that do not emit corrosive or toxic gases during combustion. This construction
significantly improves safety in fire situations while maintaining reliable
electrical performance for fixed installations.

ParameterValue
Rated Voltage450/750 V
Conductor MaterialCopper (Cu)
Conductor TypeSolid
Insulation MaterialHalogen Free, Flame Retardant Compound
Core IdentificationColor coded
Operating TemperatureMax. +70 °C
Short Circuit TemperatureMax. +160 °C
Installation TypeFixed installation
Flame RetardantIEC 60332-1
Smoke DensityLow smoke
Halogen ContentHalogen free
Toxic Gas EmissionLow
Nominal Cross Section (mm2)Overall Diameter mm (approx.)Net Weight kg/km (approx.)Conductor DC Resistance at 20°C (max. ohm/km)Current Carrying Capacity in Conduit (A)Current Carrying Capacity in Air (A)
1,52,72112,123
2,53,3347,4131
43,7504,6142
64,2713,0854
106,01161,8375
167,01611,15100
258,82580,727133161
359,53460,524164200
5011,04680,387198242
7012,56600,268253310
9515,09100,193306377
12016,511400,153354437
15018,014050,124393504
18520,017450,0991449575
24023,022950,0754528679
30026,029000,0601603783
40029,037000,0470683940
StandardDescription
IEC 60227PVC / Halogen Free Insulated Cables
IEC 60332-1Flame Retardant
CECompliant
RoHSCompliant
Application Area
Public buildings
Hospitals and schools
Commercial facilities
Industrial control panels
Areas with high fire safety requirements

Technical values are indicative and may vary depending on conductor size,
installation conditions, and applicable standards. For detailed technical data