N2XH (VDE)

0.6/1 kV halogen free XLPE insulated power cables (N2XH) are designed for power
transmission and distribution in fixed installations where enhanced fire safety,
low smoke emission, and high thermal performance are required. These cables combine
XLPE insulation with halogen free materials to provide improved current carrying
capacity and reduced toxic gas emission in case of fire.
N2XH cables are widely used in public buildings, industrial facilities, and
infrastructure projects where human safety and system reliability are critical.
Applications
- Power transmission and distribution systems
- Public buildings such as hospitals, schools, and airports
- Industrial facilities and plants
- Commercial and residential buildings
- Infrastructure and utility projects
- Areas requiring low smoke and halogen free cables
N2XH cables are preferred in installations requiring high fire safety standards,
low smoke density, and reliable electrical performance.
Cable Construction
- Conductor: Solid or stranded copper conductor
- Insulation: XLPE (Cross-Linked Polyethylene)
- Inner Sheath: Halogen free compound
- Outer Sheath: Halogen free compound
N2XH cables are constructed with XLPE insulated copper conductors and halogen free
inner and outer sheaths. This design provides excellent thermal performance,
mechanical protection, and minimal smoke and toxic gas emission during fire.
| Parameter | Value |
|---|---|
| Rated Voltage | 0.6/1 kV |
| Conductor Material | Copper (Cu) |
| Conductor Type | Solid or Stranded |
| Insulation Material | XLPE |
| Inner Sheath | Halogen Free Compound |
| Outer Sheath | Halogen Free Compound |
| Operating Temperature | Max. +90 °C |
| Short Circuit Temperature | Max. +250 °C |
| Installation Type | Fixed installation |
| Smoke Density | Low smoke |
| Halogen Content | Halogen free |
| Flame Retardant | IEC 60332-1 |
| Parameter | Description |
|---|---|
| Conductor Resistance at 20°C | According to IEC 60228 |
| Insulation Resistance | ≥ 20 MΩ·km |
| Test Voltage | 3.5 kV |
| Current Carrying Capacity | Higher than PVC insulated cables |
| Standard | Description |
|---|---|
| VDE | N2XH |
| IEC 60502-1 | Low Voltage Power Cables |
| IEC 60332-1 | Flame Retardant |
| CE | Compliant |
| RoHS | Compliant |
| Application Area |
|---|
| Public buildings |
| Industrial facilities |
| Infrastructure projects |
| Commercial buildings |
| Areas with high fire safety requirements |
| Nominal Cross Section (mm²) | Overall Diameter mm (approx.) | Net Weight kg/km (approx.) | Conductor DC Resistance at 20°C (max. ohm/km) | Current Carrying Capacity in Air (A) | Current Carrying Capacity in Ground (A) |
| 1 Core | |||||
| 1×4 | 6.7 | 77 | 4.61 | 44 | 56 |
| 1×6 | 7.2 | 98 | 3.08 | 56 | 71 |
| 1×10 | 8.51 | 142 | 1.83 | 77 | 96 |
| 1×16 | 9.0 | 200 | 1.15 | 102 | 125 |
| 1×25 | 10.5 | 300 | 0.727 | 136 | 162 |
| 1×35 | 11.6 | 398 | 0.524 | 168 | 197 |
| 1×50 | 13.1 | 525 | 0.387 | 203 | 234 |
| 1×70 | 15.0 | 732 | 0.268 | 258 | 291 |
| 1×95 | 17.2 | 1010 | 0.193 | 315 | 351 |
| 1×120 | 19.1 | 1255 | 0.153 | 365 | 403 |
| 1×150 | 21.0 | 1545 | 0.124 | 420 | 458 |
| 1×185 | 23.5 | 1915 | 0.0991 | 483 | 521 |
| 1×240 | 26.5 | 2515 | 0.0754 | 573 | 611 |
| 1×300 | 29.5 | 3140 | 0.0601 | 661 | 697 |
| 1×400 | 34.0 | 4020 | 0.0470 | 780 | 811 |
| 1×500 | 38.0 | 5100 | 0.0366 | 903 | 930 |
| 1×630 | 43.0 | 6550 | 0.0283 | 1045 | 1063 |
| 2 Cores | |||||
| 2×1.5 | 9.0 | 105 | 12.1 | 24 | 32 |
| 2×2.5 | 10.0 | 138 | 7.41 | 32 | 43 |
| 2×4 | 11.1 | 185 | 4.61 | 42 | 56 |
| 2×6 | 12.1 | 245 | 3.08 | 53 | 71 |
| 2×10 | 14.5 | 375 | 1.83 | 74 | 96 |
| 2×16 | 16.5 | 535 | 1.15 | 98 | 125 |
| 2×25 | 20.0 | 830 | 0.727 | 128 | 162 |
| 2×35 | 22.1 | 1085 | 0.524 | 157 | 197 |
| 2×50 | 25.5 | 1450 | 0.387 | 190 | 234 |
| 3 Cores | |||||
| 3×1.5 | 9.5 | 122 | 12.1 | 24 | 32 |
| 3×2.5 | 10.5 | 165 | 7.41 | 32 | 43 |
| 3×4 | 11.7 | 225 | 4.61 | 42 | 56 |
| 3×6 | 12.8 | 305 | 3.08 | 53 | 71 |
| 3×10 | 15.4 | 472 | 1.83 | 74 | 96 |
| 3×16 | 17.5 | 682 | 1.15 | 98 | 125 |
| 3×25 | 21.2 | 1065 | 0.727 | 128 | 162 |
| 3×35 | 23.5 | 1400 | 0.524 | 157 | 197 |
| 3×50 | 27.2 | 1850 | 0.387 | 190 | 234 |
| 4 Cores | |||||
| 4×1.5 | 10.3 | 148 | 12.1 | 24 | 32 |
| 4×2.5 | 11.5 | 205 | 7.41 | 32 | 43 |
| 4×4 | 12.8 | 285 | 4.61 | 42 | 56 |
| 4×6 | 14.1 | 390 | 3.08 | 53 | 71 |
| 4×10 | 16.8 | 610 | 1.83 | 74 | 96 |
| 4×16 | 19.2 | 885 | 1.15 | 98 | 125 |
| 4×25 | 24.5 | 1420 | 0.727 | 128 | 162 |
| 4×35 | 27.2 | 1870 | 0.524 | 157 | 197 |
| 4×50 | 31.2 | 2530 | 0.387 | 190 | 234 |
| 4×70 | 36.0 | 3580 | 0.268 | 242 | 291 |
| 4×95 | 41.2 | 4930 | 0.193 | 293 | 351 |
| 4×120 | 46.0 | 6250 | 0.153 | 339 | 403 |
| 4×150 | 51.5 | 7740 | 0.124 | 389 | 458 |
| 4×185 | 57.5 | 9750 | 0.0991 | 444 | 521 |
| 4×240 | 66.0 | 12850 | 0.0754 | 522 | 611 |
| 5 Cores | |||||
| 5×1.5 | 11.2 | 178 | 12.1 | 24 | 32 |
| 5×2.5 | 12.5 | 248 | 7.41 | 32 | 43 |
| 5×4 | 13.6 | 349 | 4.61 | 42 | 52 |
| 5×6 | 14.9 | 460 | 3.08 | 53 | 64 |
| 5×10 | 18.2 | 722 | 1.83 | 73 | 86 |
| 5×16 | 21.0 | 1052 | 1.15 | 96 | 111 |
| 5×25 | 25.0 | 1585 | 0.727 | 130 | 143 |
| 5×35 | 28.1 | 2121 | 0.524 | 160 | 173 |
| 5×50 | 37.0 | 2838 | 0.387 | 195 | 205 |
| 5×70 | 37.2 | 4008 | 0.268 | 247 | 252 |
| 5×95 | 42.0 | 5374 | 0.193 | 305 | 303 |
| 5×120 | 48.0 | 6897 | 0.153 | 355 | 346 |
| 3.5 Cores (Reduced Neutral) | |||||
| 3×16+10 | 18.2 | 815 | 1.15 / 1.83 | 98 | 125 |
| 3×25+16 | 22.1 | 1250 | 0.727 / 1.15 | 128 | 162 |
| 3×35+16 | 24.1 | 1585 | 0.524 / 1.15 | 157 | 197 |
| 3×50+25 | 28.0 | 2185 | 0.387 / 0.727 | 190 | 234 |
| 3×70+35 | 32.1 | 3040 | 0.268 / 0.524 | 242 | 291 |
| 3×95+50 | 36.6 | 4125 | 0.193 / 0.387 | 293 | 351 |
| 3×120+70 | 40.5 | 5225 | 0.153 / 0.268 | 339 | 403 |
| 3×150+70 | 44.5 | 6360 | 0.124 / 0.268 | 389 | 458 |
| 3×185+95 | 50.0 | 8025 | 0.0991 / 0.193 | 444 | 521 |
| 3×240+120 | 57.5 | 10450 | 0.0754 / 0.153 | 522 | 611 |
Technical values are indicative and may vary depending on conductor size,
installation conditions, and applicable standards. For detailed technical data