0.6/1 kV Fire Resistant Halogen Free XLPE Power Cables(N2XH FE180)

N2XH FE 180 / E30 – E90 (VDE)

0.6/1 kV fire resistant halogen free XLPE insulated power cables (N2XH FE 180) are
designed to maintain circuit integrity for a specified period during fire
conditions. These cables ensure continuous power supply to critical systems such
as emergency lighting, fire alarm systems, and safety equipment.

N2XH FE 180 cables combine halogen free materials with fire resistant construction,
providing low smoke emission, minimal toxic gas release, and reliable electrical
performance under extreme conditions.

Applications

  • Emergency power supply systems
  • Fire alarm and evacuation systems
  • Emergency lighting installations
  • Smoke extraction and ventilation systems
  • Public buildings such as hospitals, airports, and tunnels
  • Infrastructure projects requiring circuit integrity during fire

N2XH FE 180 cables are used in safety-critical installations where electrical
circuits must remain operational for a defined time during fire exposure.

Cable Construction

  • Conductor: Solid or stranded copper conductor
  • Insulation: XLPE (Cross-Linked Polyethylene)
  • Fire Resistant Layer: Mica tape
  • Inner Sheath: Halogen free compound
  • Outer Sheath: Halogen free compound

N2XH FE 180 cables are constructed with XLPE insulated copper conductors wrapped
with mica tape to ensure circuit integrity during fire. The halogen free inner and
outer sheaths provide low smoke density and minimal toxic gas emission, enhancing
safety for people and critical systems.

ParameterValue
Rated Voltage0.6/1 kV
Conductor MaterialCopper (Cu)
Conductor TypeSolid or Stranded
Insulation MaterialXLPE
Fire Resistant LayerMica tape
Inner SheathHalogen Free Compound
Outer SheathHalogen Free Compound
Operating TemperatureMax. +90 °C
Short Circuit TemperatureMax. +250 °C
Fire ResistanceFE 180
Circuit IntegrityE30 / E60 / E90
Smoke DensityLow smoke
Halogen ContentHalogen free
Flame RetardantIEC 60332-1
ParameterDescription
Conductor Resistance at 20°CAccording to IEC 60228
Insulation Resistance≥ 20 MΩ·km
Test Voltage3.5 kV
Current Carrying CapacityAccording to installation method
StandardDescription
VDEN2XH FE 180
DIN 4102-12Circuit Integrity (E30–E90)
IEC 60331Fire Resistance
IEC 60332-1Flame Retardant
CECompliant
RoHSCompliant
Application Area
Emergency systems
Fire safety installations
Public buildings
Tunnels and underground facilities
Infrastructure projects
Nominal Cross Section (mm²)Overall Diameter mm (approx.)Net Weight kg/km (approx.)Conductor DC Resistance at 20°C (max. ohm/km)Current Carrying Capacity in Air (A)Current Carrying Capacity in Ground (A)
1 Core
1×47,51004,614456
1×68,01233,085771
1×108,91711,837796
1×169,82341,15102128
1×2511,23360,727136168
1×3512,34410,524168203
1×5013,85760,387203240
1×7015,67880,268258299
1×9517,910730,193315351
1×12019,813240,153365403
1×15021,716140,124420458
1×18524,120110,0991483521
1×24027,226230,0754573611
1×30030,232620,0601661697
1×40034,741650,047780811
2 Cores
2×1,511,820112,12432
2×2,512,62397,413243
2×413,52964,614256
2×614,53653,085371
2×1016,14961,837496
2×1618,36821,1598125
2×2522,210450,727128162
2×3524,713350,524157197
2×5028,518050,387190234
3 Cores
3×1,512,422412,12432
3×2,513,32727,413243
3×414,23444,614256
3×615,34303,085371
3×1017,05981,837496
3×1619,38421,1598125
3×2523,512870,727128162
3×3526,116750,524157197
3×5030,322750,387190234
3.5 Cores (Reduced Neutral)
3×16+1020,410121,15/1,8398125
3×25+1624,915020,727/1,15128162
3×35+1627,218880,524/1,15157197
3×50+2531,626020,387/0,727190234
3×70+3536,536580,268/0,524242291
3×95+5041,550120,193/0,387293351
3×120+7046,263280,153/0,268339403
3×150+7051,277450,124/0,268389458
3×185+9557,698660,0991/0,193444521
3×240+12065,8128450,0754/0,153522611
4 Cores
4×1,513,426212,12432
4×2,514,43237,413243
4×415,54134,614256
4×616,75253,085371
4×1018,67411,837496
4×1621,210561,1598125
4×2525,916360,727128162
4×3528,921450,524157197
4×5033,629400,387190234
4×7038,940820,268242291
4×9544,455300,193293351
Control Cables
7×1,516,037012,11615
10×1,519,550612,11414
12×1,520,257112,11313
14×1,521,264312,11212
19×1,524,083012,11211
21×1,525,191112,11111
24×1,527,6104212,11010
30×1,529,7125112,11010
40×1,533,2161012,199
48×1,536,5192812,198
61×1,540,2237412,188
7×2,517,54657,412120
10×2,521,36427,411918
12×2,522,17287,411817
14×2,523,28277,411616
19×2,526,110647,411514
21×2,527,411687,411414
24×2,530,213417,411313
30×2,532,516227,411212
40×2,536,421017,411212
48×2,540,324857,41109
61×2,544,230587,41109

Fire resistance and circuit integrity classifications depend on installation
method and system configuration. For project-specific requirements and compliance,
please contact Envoltra Cable.

Contact & Inquiry

For fire resistant cable solutions, technical details, and project-based pricing,
please contact Envoltra Cable sales team.